Electromagnetic pulse valve model DCF-Y-62S
Installation reference dimensions with gas distribution box and nozzle connector A Φ75.5
B Φ148
C Φ208
D 35
E 44
F Φ188
G 230
R
N-φ 6-φ11

     

technical standard
 
       Working pressure: 0.2~0.6MPa
       Working medium: clean air
       Voltage: DC24V, (AC220V/50HZ)
       Use environment:
       1 temperature: normal temperature diaphragm -25 ° C ~ 85 ° C
                    High temperature diaphragm -25 ° C ~ 230 ° C
                    Low temperature diaphragm -40 ° C ~ 80 ° C
       2 The relative humidity of the air does not exceed 85%
       Protection level: IP65

 

       Diaphragm life: 5 years or 1 million times

 