DCF-Y-50S

author: xiechang editor: xiechang source: xiechang time: 2019-04-15 09:15:08
Abstract:
Electromagnetic pulse valve modelDCF-Y-50SInstallation reference dimensions with gas distribution box and nozzle conne

 

 

\\

Electromagnetic pulse valve model DCF-Y-50S
Installation reference dimensions with gas distribution box and nozzle connector A Φ60.5
B Φ122
C Φ180
D 30
E 39
F φ160
G 202
R
N-φ 6-φ11

   

technical standard
 
       Working pressure: 0.2~0.6MPa
       Working medium: clean air
       Voltage: DC24V, (AC220V/50HZ)
       Use environment:
       1 temperature: normal temperature diaphragm -25 ° C ~ 85 ° C
                    High temperature diaphragm -25 ° C ~ 230 ° C
                    Low temperature diaphragm -40 ° C ~ 80 ° C
       2 The relative humidity of the air does not exceed 85%
       Protection level: IP65
       Diaphragm life: 5 years or 1 million times

 

 

反馈建议