DCF-ZM-40S

author: xiechang editor: xiechang source: xiechang time: 2019-04-15 09:02:09
Abstract:
Electromagnetic pulse valve modelDCF-ZM-40SConnecting the vent tube outer diameter(mm)Φ48size(mm)A103B78C51D42E236

\\

 

Electromagnetic pulse valve model DCF-ZM-40S
Connecting the vent tube outer diameter (mm) Φ48
size(mm) A 103
B 78
C 51
D 42
E 236
F 170
G 13.3
φ 112















technical standard

 
       Working pressure: 0.4~0.6MPa
       Working medium: clean air
       Voltage: DC24V, (AC220V/50HZ)
       Use environment:
       1 temperature: normal temperature diaphragm -25 ° C ~ 85 ° C
                    High temperature diaphragm -25 ° C ~ 230 ° C
                    Low temperature diaphragm -40 ° C ~ 80 ° C
       2 The relative humidity of the air does not exceed 85%
        Protection level: IP65
        Diaphragm life: 5 years or 1 million times

 