SXC-8B2-6416

author: xiechang editor: xiechang source: xiechang time: 2019-04-15 10:08:25
Abstract:
SXC-8B2 offline pulse controller (including air box pulse)SXC-8B2 pulse controller works Bag clean and off-lin

 

SXC-8B2 offline pulse controller (including air box pulse)
SXC-8B2 pulse controller works
 
        Bag clean and off-line cleaning means stopping filtration when cleaning. This system divides the interior of the precipitator into several sealed air chambers, each of which is alternately cleaned in turn, and the air outlets on the panels of each air chamber are independently installed with a compressed air control system such as a baffle, a cylinder and a solenoid valve. Before the pulse cleaning operation of a certain air chamber, it is necessary to first close the baffle so that the air chamber is no longer filtered by the flue gas.
 
Controller model specifications
脉冲控制仪型号 控制提升阀 电磁脉冲阀数 外壳材料 外形尺寸 整机重量
SXC-8B2-6416 1 – 64 1 – 16 铝合金台式 160×300×330 6KG
SXC-8B2-2401 1 – 24 1

 

Note: 1. The specific number of lift valves is proposed by the user when ordering, but it must be a single coil cylinder solenoid valve.
          2. The shell form of the offline pulse controller will be changed according to the needs of the number of output channels. Please confirm before ordering.
 
SXC-8B2 pulse controller technical parameters and indicators
 
Pulse controller rated input voltage AC220V (±10%) 50HZ/60HZ
Pulse controller rated output voltage DC24V/AC220V (or other custom specifications)
Pulse controller rated output current 1A
Pulse waiting (that is, the poppet valve is closed or turned on for 8 seconds before going to the next step) 8 seconds / S (not adjustable)
Output pulse width adjustment range 0.02-2.55 seconds (S)
Output pulse interval adjustment range 1-255 sec / s (the air box pulse does not have this item)
Lift valve sink will adjust the range 1-255 seconds / S
Poppet valve interval adjustment range 1-255 sec / S
Cycle (the time interval from one pulse to the next cycle for all pulse valves) 0-255 min/min
Number of offline valves (ie, number of units) select 1-64 PCS
Number of pulse valves selected 1-16 PCS
Differential pressure control input signal Differential pressure display and differential pressure transmitter
Pulse controller use ambient temperature -20 ° C ~ +50 ° C; air relative humidity does not exceed 85%; no severe corrosive gases and conductive dust; no severe vibration or impact;
 
SXC-8B2 pulse controller instructions
1. After the controller is connected to the power supply, the digital display of the pulse controller digitally starts from the poppet valve "1". Set at the factory timing;
2. Adjust the pulse controller time parameter: Turn the third gear switch to the “select” position (the air box pulse computer controller is turned to “adjust”):
(1) The pulse controller displays the “pulse width” parameter (factory setting is 0.08 seconds), press the “plus” and “minus” buttons until the desired value is reached;
(2) Press the “Check/Select” button to display the “Interval” parameter (the factory has been set to 8 seconds, the air box pulse controller does not have this item), press the “Plus” and “Subtract” buttons until the required value is reached;
(3) Press the “Check/Select” button, the pulse controller displays the “Settling” parameter (factory has been set to 8 seconds), press the “Add” and “Subtract” buttons until the required value is reached;
(4) Press the “Check/Select” button, the pulse controller displays the “Intermittent” parameter (the factory has been set to 10 seconds), press the “Plus” and “Subtract” buttons until the required value is reached;
(5) Press the “Check/Select” button, the pulse controller displays the “Cycle” parameter (factory has been set at 0), press the “Add” or “Subtract” button until the desired value is reached;
(6) Press the “Check/Select” button, the pulse controller displays the “Number of Times” parameter (factory has been set at 0 times);

 

3. Turn the third gear switch of the pulse controller to the “Run” position, and the controller will clean the machine according to the set time parameters. The differential pressure control is required to be submitted by the user.