SXC-X8A5

author: xiechang editor: xiechang source: xiechang time: 2019-04-15 09:57:16
Abstract:
A three-in-one integrated control instrument that combines an online pulse controller, differential pressure displa

 

 

   A three-in-one integrated control instrument that combines an online pulse controller, differential pressure display, and differential pressure sensor for optimal resource optimization.

        There is a digital display on the panel, which can display the working sequence of the electromagnetic pulse valve in turn. According to the cleaning requirements, the pulse width, pulse interval and cycle interval, output loop can be adjusted, the solenoid valve can be controlled to open and close, and the dust collector can be regularly cleaned. . At the same time, it can be changed to differential pressure cleaning. Only by connecting the air pipe to the machine, intelligent control can be realized under the combined control of seven differential pressure parameters.
        In order to facilitate the user to freely combine the number of electromagnetic pulse valves controlled, the expansion output module can be used to increase or decrease the number of controls.

Three-in-one differential pressure control X8A5:\


 

SXC-8A5 online pulse controller model specifications:

型号 控制电磁脉冲阀数 类型 外壳材料 扩展模块数 主壳外形尺寸 扩展模块外形尺寸 净重
SXC-X8A5-XX 1 – 16 单机 透明PC塑壳 0 100×250×200   1.7
17 – 26 组合 1 100×250×200 55×130×190 2.3
27 – 36 1 100×250×200 55×130×190 2.3
37 – 46 1 100×250×200 55×130×190 2.3
47 – 56 1 100×250×200 55×130×190 2.3
57 - 96 2 100×250×200 (55×130×190)×2 2.9


 

 

 

 

 

 

 

 

 

Technical parameters and indicators of SXC-8A5 pulse controller:

额定输入电压 AC220V(±10%)50HZ/60HZ
额定输出电压 DC24V/AC220V(或其他订制规格)
额定输出电流 1A
耗电 ≤8W
输出脉冲宽度调节范围 0.02-2.55 S
输出脉冲间隔调节范围 1-255 S
周期(全部脉冲阀循环一次后到下一循环的时间间隔) 1-255 Min
控制电磁脉冲阀的个数 1-96
控制方式 定时/定压差
差压控制输入信号 差压控制仪和差压变送器
使用环境 工作温度-20℃ ~ +50℃;空气相对湿度不超过85%;无严重腐蚀气体和导电尘埃;无剧烈震动或冲击;


 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the user has special requirements for the parameters, please submit them at the time of ordering.


SXC-8A5 pulse controller instructions:

\

SXC-8A5 pulse controller works:
      (1) The pulse controller turns on the power supply AC220V, and the pulse controller side switch is turned to the "timing" position. Press the reset button. At this time, the controller runs in the "timing" mode. The differential pressure display is normal but its parameters are incorrect. The cleaning operation status has an effect. High and low alarms are still valid.
      (2) Turn the pulse controller side switch to the “constant pressure” position and press the reset button. At this time, the controller runs in the “constant pressure” mode, and the differential pressure setting parameter will control the start and stop of the cleaning.
 
 
Parameter adjustment:
(1) Turn the pulse controller 3-position switch to the pulse adjustment position:
        At this time, the "pulse width" light is on, the time parameter is displayed as 0.08, the unit is second, and the adjustment range is 0.02-2.55s;
        Press the “Time Adjustment” button, the “Interval” light will be on, the time parameter will display 10, the unit is second, and the adjustment range is 0-255s.
        Press the “Time Adjustment” button, the “Cycle” light will be on at this time, the time parameter will display 0, the unit is minute, and the adjustment range is 0-255m.
        Press the “Time Adjustment” button, the “Loop” light will be on, the time parameter will display N, and the adjustment range will be 1-96.
 
 
(2) Turn the 3-way switch of the pulse controller to the differential pressure adjustment position:
       At this time, the differential pressure display digital tube displays "P 1.00", "P" indicates the injection start value, and "1.00" indicates that the pulse injection start when the differential pressure resistance is greater than 1KP. Adjustment range: 4.00-0.00KP
       Press “Pressure setting”, at this time, the differential pressure display digital tube displays “q 0.20”, “q” indicates the difference of the injection back, and “0.20” indicates that the differential pressure resistance is less than the “injection starting value of -0.20”. The blow stops after completing this cycle. Adjustment range: 0.50-0.00KP.
       Press the pulse controller "pressure difference setting". At this time, the differential pressure display digital tube displays "H 1.80", "H" indicates the high alarm value, and "1.80" indicates the high alarm output when the differential pressure resistance is greater than 1.80KP. The light is on and the passive contact "K2-1, K2-2" is closed. Adjustment range: 4.00-0.00KP
       Press the pulse controller "pressure difference setting". At this time, the differential pressure display digital tube displays "d 0.10", "d" indicates the high alarm return value, and "0.10" indicates that the differential pressure resistance is less than the "high alarm value -0.10". The high alarm output stops. Adjustment range: 0.50-0.00KP.
       Press the pulse controller "pressure difference setting". At this time, the differential pressure display digital tube displays "L 0.60", "L" indicates the low alarm value, and "0.60" indicates the low alarm output when the differential pressure resistance is less than 0.60KP. Low alarm indication The light is on and the passive contact "K1-1, K1-2" is closed. Adjustment range: 4.00-0.00KP
       Press the pulse controller "pressure difference setting". At this time, the differential pressure display digital tube displays "b 0.05, "b" indicates low alarm return value, and "0.05" indicates that the differential pressure resistance is lower than "low alarm value -0.05". The alarm output stops. The adjustment range is 0.50-0.00KP.
       Press the pulse controller "pressure difference setting", at this time the differential pressure display digital tube displays "0.00" or other numbers. This value is a stress test
       Correction value, size: When the fan is not turned on, the display value and the correction value are summed to 0; the adjustment range is -0.50-0.50.
 
 
Parameters Table:
参数名称 指示标识 出厂设置值 可设定范围
时间参数 脉宽 0.08 0.02 – 2.55s
间隔 10 0 – 255s
周期 0 0 – 255m
回路 N 1 – 96路
压差参数 喷吹启动值 P 1.00 0.00 – 4.00KP
喷吹回差值 q 1.00 0.00 – 0.50KP
高报警值 H 1.80 0.00 – 4.00KP
高报警回差值 d 0.10 0.00 – 0.50KP
低报警值 L 0.60 0.00 – 4.00KP
低报警回差值 b 0.05 0.00 – 0.50KP
压力测试校正值 -0.50 – 0.50 -0.50 – 0.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SXC-8A5 pulse controller wiring diagram:
Main box wiring diagram:

\



Install the expansion box icon:

\

 

 